Climate equipment · Free delivery in Tashkent
Ducted air conditioners

Welkin KAN

In stock
Reviews
19 440 000 UZS

For Welkin KAN 60 · equipment price

Choose capacity

Capacity class. Room area is a guide.

Free delivery within Tashkent

Installation quoted separately

Equipment sales in Tashkent and across Uzbekistan.

Just your name and phone. No payment — a manager confirms the details.

Specifications and package contentsAll specifications and what’s included

About this model

Welkin KAN 60 is a ducted split system with 17 kW cooling capacity and R410A refrigerant.

  • Concealed installation
  • Wired control
  • R410A refrigerant
Description and features

Rated cooling power input is 6938 W. Detailed cooling, heating and installation specifications are listed below.

About the series

Welkin KAN is a ducted split system. Compare capacities, power consumption, dimensions and installation requirements. Specifications depend on the selected variant.

Designed for your comfort

Why choose this model

Concealed installation

The indoor unit sits above the ceiling and supplies air through ductwork.

Wired control

Adjust the air conditioner using a wired controller.

R410A refrigerant

Refrigerant type and charge are listed in the specifications.

Technical specifications

Selected modelKAN 60
Full specifications
Model details
BrandWelkin
SeriesKAN
ModelKAN 60
Air conditioner typeDucted
AvailabilityIn stock
Compressor capacity, W16400/20300
Performance
Recommended area107 m²
Cooling capacity17 kW
Cooling capacity, BTU/h58000
Heating capacity, BTU/h60000
Heating capacity, kW17.58
Airflow, high/medium/low, m³/h2650/1850/1450
Outdoor airflow, m³/h6500
Indoor temperature, cooling, °C17–32
Indoor temperature, heating, °C0–27
Outdoor temperature, cooling, °C-7–43
Outdoor temperature, heating, °C-7–24
Cooling application area in specification, m²73–107
Power and efficiency
Power input6.938 kW
CompressorFixed speed
Energy efficiencyNot verified
Power supply380–415 V / 3 phase / 50 Hz
Rated cooling power input, W6938.297
Rated cooling current, A14.388
Cooling EER, W/W2.45
Rated heating power input, W5156.89
Rated heating current, A10.2
Heating COP, W/W3.41
System nameplate power input, W7500
System nameplate current, A12.6
Starting current in specification, A73
Compressor mechanismScroll
Compressor brandPANASONIC
Compressor power input, W5750/6750
Compressor rated load current RLA, A9.77/9.84
Compressor locked rotor current LRA, A63/68
Compressor thermal protector locationInternal
Compressor oil / charge, mlFV68S/1700
Indoor fan motor power input, W430.0
Indoor fan capacitor, µF10
Outdoor fan motor power input, W162.0
Outdoor fan capacitor, µF3.5
Power plugNo plug
Comfort and controls
Noise level42 dB· Sound pressure at low indoor fan speed. The specification does not state measurement conditions.
Wi-FiTo be confirmed
Indoor fan speeds in specification, rpm790/715/620/540
Indoor sound pressure, high/medium/low, dB(A)50.5/45/42
Outdoor fan speed, rpm765
Outdoor sound pressure level, dB(A)63
Temperature controlWired control
Dimensions and installation
Indoor coil: number of rows3.0
Indoor coil: tube pitch × row pitch, mm21 × 13.37
Indoor coil: fin spacing, mm1.3
Indoor coil: fin materialHydrophilic aluminum
Indoor coil: tube diameter and typeØ7 mm, internally grooved
Indoor coil section dimensions, L×H×W, mm1055 × 357 × 40.11
Indoor coil: number of circuits8
Indoor dimensions, W×H×D, mm1200 × 380 × 625
Indoor packing dimensions, W×H×D, mm1485 × 460 × 675
Indoor weight, net/gross, kg52.2/60.2
Outdoor coil: number of rows2
Outdoor coil: tube pitch × row pitch, mm21 × 22
Outdoor coil: fin spacing, mm1.3
Outdoor coil: fin materialHydrophilic aluminum
Outdoor coil: tube diameter and typeØ7 mm, internally grooved
Outdoor coil dimensions, L×H×W, mm830 × 22 × 630+795 × 22 × 630
Outdoor coil: number of circuits8
Outdoor dimensions, W×H×D, mm900 × 1170 × 350
Outdoor packing dimensions, W×H×D, mm1032 × 1307 × 443
Outdoor weight, net/gross, kg99.7/111.2
RefrigerantR410A
Refrigerant charge, kg3.3
Design pressure, high/low, MPa4.2/1.5
Pipe diameter, liquid/gas9.52 / 19 mm
Maximum pipe length, m50
Maximum height difference, m30
Interconnecting cable2.5 × 5/1.0 × 3
Power cable section and cores in specification2.5 × 5
Additional specifications
Set temperature range, °C17–30
Sets per 20′/40′/40′HQ container0/0/0

A specification guideline. Final sizing depends on ceiling height, glazing, occupancy and heat load.

Power consumption in cooling mode
Cooling power input

6 938 W

Rated consumption

Actual consumption depends on conditions and settings.

What’s included & documents

Full package contents and warranty documents are confirmed when ordering.

Delivery, installation & warranty

Delivery in Tashkent is free. Installation is a separate service with an agreed quote. Delivery timing and warranty terms are confirmed before purchase.

Official warranty across Uzbekistan. Duration depends on the model documents.

Delivery termsWarranty service

Owner experiences

Product reviews

Loading reviews…

Publication policy

We publish relevant product experiences, including negative reviews. Spam, abuse, personal details and unrelated content are hidden. Purchases are not verified.