Midea Tiba 48 is a ducted split system with 14.36 kW cooling capacity and R410A refrigerant.
Rated cooling power input is 5128 W. Detailed cooling, heating and installation specifications are listed below.
Midea TIBA is a ducted split system. Compare capacities, power consumption, dimensions and installation requirements. Specifications depend on the selected variant.
The indoor unit sits above the ceiling and supplies air through ductwork.
Adjust the air conditioner using a wired controller.
Refrigerant type and charge are listed in the specifications.
| Brand | Midea |
|---|---|
| Series | TIBA |
| Model | Tiba 48 |
| Air conditioner type | Ducted |
| Availability | In stock |
| Compressor capacity, BTU/h | 48109 |
| Recommended area | To be confirmed |
|---|---|
| Cooling capacity | 14.36 kW |
| Cooling capacity, BTU/h | 49000 |
| Heating capacity, BTU/h | 52000 |
| Heating capacity, kW | 15.24 |
| Airflow, high/medium/low, m³/h | 2656/2373/2115 |
| External static pressure, rated, Pa | 50 |
| External static pressure range, Pa | 0-200 |
| Indoor temperature, cooling, °C | 17–32 |
| Indoor temperature, heating, °C | 0–30 |
| Outdoor airflow, m³/h | 6000 |
| Outdoor temperature, cooling, °C | 18–43 |
| Outdoor temperature, heating, °C | -7–24 |
| Power input | 5.128 kW |
|---|---|
| Compressor | Fixed speed |
| Energy efficiency | Not verified |
| Power supply | 380–415 V / 3 phase / 50 Hz |
| Rated cooling power input, W | 5128 |
| Rated cooling current, A | 9 |
| Cooling EER, W/W | 2.8 |
| Rated heating power input, W | 4220 |
| Rated heating current, A | 7.4 |
| Heating COP, W/W | 3.61 |
| Indoor fan motor power input, W | 588 |
| Indoor fan capacitor, µF | 10 |
| Maximum power input, W | 6300 |
| Maximum current, A | 11 |
| Compressor mechanism | Scroll |
| Compressor brand | Panasonic |
| Compressor power input, W | 4750 |
| Compressor rated load current RLA, A | 8.220000000000001 |
| Compressor locked rotor current LRA, A | 66 |
| Compressor thermal protector location | Internal |
| Compressor oil / charge, ml | FV68S 1700 |
| Outdoor fan motor power input, W | 162 |
| Outdoor fan capacitor, µF | 3.5 |
| Noise level | 46 dB· Sound pressure at low indoor fan speed. The specification does not state measurement conditions. |
|---|---|
| Wi-Fi | To be confirmed |
| Indoor fan speed, high/medium/low, rpm | 750/705/655 |
| Indoor sound pressure, high/medium/low, dB(A) | 51/49/46 |
| Temperature control | Wired control |
| Outdoor fan speed, rpm | 765 |
| Outdoor sound pressure level, dB(A) | 63 |
| Indoor coil: number of rows | 3 |
|---|---|
| Indoor coil: tube pitch × row pitch, mm | 21 × 13.37 |
| Indoor coil: fin spacing, mm | 1.3 |
| Indoor coil: fin material | Hydrophilic aluminum, golden coating |
| Indoor coil: tube diameter and type | Ø7 mm, internally grooved |
| Indoor coil section dimensions, L×H×W, mm | 1055 × 357 × 40.11 |
| Indoor coil: number of circuits | 8 |
| Indoor dimensions, W×H×D, mm | 1200 × 380 × 625 |
| Indoor packing dimensions, W×H×D, mm | 1485 × 450 × 675 |
| Indoor weight, net/gross, kg | 46/52.3 |
| Design pressure, high/low, MPa | 4.2/1.5 |
| Drain pipe outside diameter, mm | Ø25 |
| Pipe diameter, liquid/gas | 9.52 / 19 mm |
| Outdoor coil: number of rows | 2 |
| Outdoor coil: tube pitch × row pitch, mm | 21 × 13.37 |
| Outdoor coil: fin spacing, mm | 1.4 |
| Outdoor coil: fin material | Hydrophilic aluminum, golden coating |
| Outdoor coil: tube diameter and type | Ø7 mm, internally grooved |
| Outdoor coil dimensions, L×H×W, mm | 840 × 1113 × 26.74 |
| Outdoor coil: number of circuits | 8 |
| Outdoor dimensions, W×H×D, mm | 900 × 1170 × 350 |
| Outdoor packing dimensions, W×H×D, mm | 1032 × 1307 × 443 |
| Outdoor weight, net/gross, kg | 93.2/105 |
| Refrigerant | R410A |
| Refrigerant charge, kg | 3.25 |
| Maximum pipe length, m | 50 |
| Maximum height difference, m | 30 |
| Indoor fan motor quantity | 1 |
|---|---|
| Outdoor fan motor quantity | 2 |
| Expansion device type | Capillary tube |
A specification guideline. Final sizing depends on ceiling height, glazing, occupancy and heat load.
5 128 W
Rated consumption
Actual consumption depends on conditions and settings.
Full package contents and warranty documents are confirmed when ordering.
Delivery in Tashkent is free. Installation is a separate service with an agreed quote. Delivery timing and warranty terms are confirmed before purchase.
Official warranty across Uzbekistan. Duration depends on the model documents.
Delivery termsWarranty serviceOwner experiences
Loading reviews…
We publish relevant product experiences, including negative reviews. Spam, abuse, personal details and unrelated content are hidden. Purchases are not verified.
Capacity and room area
Room area is a guide.
Capacity and room area
Room area is a guide.
Capacity and room area
Room area is a guide.