Climate equipment · Free delivery in Tashkent
WELKIN · COMMERCIAL CLIMATE

VRF systems.
Built for your project's scale.

One air conditioning system for multiple rooms. Individual comfort in every zone, from an office to an entire building.

3-year equipment and installation warranty
Modera Towers — a completed Welkin projectOUR PROJECTS Modera Towers
Across UzbekistanFrom selection to maintenance
Extensive warehouseMost equipment in stock
2 monthsLead time for special orders
THE WELKIN ADVANTAGE

Reliability.
At every stage.

From choosing your system to maintaining it — experience, warranty and support at your side.

Discuss your project
36 months

Warranty

On equipment and installation

24/7

Customer support

Available and ready to help

15

Service centres

Across Uzbekistan

15+

Years of experience

In climate equipment

10 000+

Finished units in warehouses

3 000+

Projects worldwide

ABB & KUKA

Robotic assembly

Defect rate stated in the catalogue: 0.0001%.

EUROVENT
AHRI · ISO

International certification

Brand figures and certification information are from the Welkin catalogue. Certificates for your chosen series are confirmed during quotation.

FROM A ROOM TO A WHOLE BUILDING

Your property.
Its own comfort system.

Choose an application and explore how the solution comes together.

01 / 03

Your whole home. Your climate.

A cool living room, a comfortable bedroom and control from your phone. We select equipment to suit your home’s layout and interior.

  • Room-by-room temperature
  • Concealed ducted or wall-mounted units
  • Schedules and remote control
Home with Hi-Mit II control — Welkin catalog illustration
Application illustration · Welkin catalog
Outdoor unit

Installed outdoors or in a technical space specified by the project. Heat rejection and service access are considered during selection.

View details

These scenarios illustrate system capabilities. Capacity, compatibility, pipework and equipment are calculated for your property.

EQUIPMENT CATALOGUE

Find your project's solution.

Price on request. Availability of your configuration is confirmed with the quote.

Series found: 19

CLIMATE UNDER YOUR CONTROL

One touch.
The right atmosphere.

From adjusting one room to managing an entire building.

From your phone
Hi-Mit II

Hi-Mit II

Control the climate on your way home. Set up rooms and schedules in the Hi-Mit app.

  • Up to 64 indoor units per adapter
  • 7 × 24 scheduling and custom scenarios
  • Up to 8 adapters in one account
Connection requirements

Requires compatible equipment, a Hi-Mit II adapter and internet access. Supports two-level user permissions and online diagnostics; energy monitoring requires meters. Adapter: 91 × 117 × 31 mm, 12 V supply, 2.4 W consumption. Catalog: pages 178–179.

From one panel
Smart Touch II

Smart Touch II

Every room on one touchscreen. Convenient for managing a hotel, office or large home.

  • 10-inch screen · 1280 × 800
  • Up to 160 indoor and 64 outdoor units
  • Weekly and holiday timer
Connection requirements

Supports 14 languages including Russian, local and web control, email fault notifications, and OTA and USB updates. Size: 170 × 252 × 37 mm. Energy-monitoring functions depend on the configuration. Catalog: pages 174–175.

Across the building
Hi-Dom III

Hi-Dom III

Computer-based control: rooms on a floor plan, operating history and system monitoring.

  • Rooms and units on the building floor plan
  • Operation history and Excel export
  • Up to 5,120 indoor units with 32 adapters
Connection requirements

One adapter connects up to 160 indoor units. Includes user permissions, temperature limits, timers and a fault log. Energy metering and allocation require suitable adapters and meters. Catalog: pages 180–181.

SMART HOME AND AUTOMATION

Climate is part of the whole system.

BACnet, Modbus and KNX gateways connect compatible equipment to building management. We coordinate capabilities with your designer.

How it connects to the building

The gateway sends commands and equipment status to the building management system: on/off, mode, temperature, fan speed and faults. BACnet, Modbus or KNX is selected for the automation project; connection capacity depends on the gateway.

We select the protocol, gateway capacity and required functions together with the automation designer. Catalog: pages 184–185.

EVERY DETAIL CONSIDERED

Complete your system.

Select the features you need. We will include them in your enquiry and check compatibility.

Hi-MotionComfort

Hi-Motion

Detects occupant activity and helps manage comfort without constant manual adjustments.

Features and compatibility

How it works

A separate sensor mounts on the wall or ceiling. The system can switch the unit off when the room is empty and adjust temperature and airflow as activity changes.

  • Ceiling coverage up to 30 m² according to the catalog
  • Wall or ceiling mounting
  • Automatic switch-off when unoccupied

Where it helps

Meeting rooms, offices and other spaces used intermittently.

Compatibility

Listed for all indoor unit types in the catalog. Functions and wiring are checked for the selected configuration. Sold as a separate option.

Catalog pages 33, 187
Motion sensor for cassette unitsComfort

Motion sensor for cassette units

Fits into the cassette panel and adjusts air delivery according to occupancy.

Features and compatibility

How it works

Switches the unit on or off as people arrive or leave. Supports airflow toward or away from occupants and temperature adjustment based on occupancy.

  • Installation in the decorative panel
  • Direct airflow or draft avoidance
  • Automatic occupancy-based control

Where it helps

Offices and public spaces with cassette units.

Compatibility

Four-way cassettes and mini-cassettes use different sensors. Selected together with a compatible panel.

Catalog pages 33, 187
Humidity sensorComfort

Humidity sensor

Adds humidity monitoring and automatic dehumidification.

Features and compatibility

How it works

Provides humidity readings to the system. The catalog specifies a 35–90% setting range for compatible configurations. This is a dehumidification function; the sensor itself does not humidify the air.

  • Relative humidity monitoring
  • Automatic dehumidification
  • 35–90% setting range for compatible systems

Where it helps

Spaces where controlling humidity is as important as temperature.

Compatibility

Listed for four-way cassettes, mini-cassettes, console, ceiling ducted and floor units. Function availability depends on the configuration.

Catalog pages 37, 187
Filters and filter unitsAir

Filters and filter units

Filtration matched to the indoor unit and ventilation requirements.

Features and compatibility

How it works

The catalog includes G4 cassette filters, a G1 filter for specified ducted and fresh-air models, and separate filter boxes with a G4 + F7 + F9 combination.

  • Replacement filters for cassette units
  • Separate filter boxes
  • Filter grade and size matched to the model

Where it helps

Projects with additional supply-air filtration requirements.

Compatibility

Filters are not universal. We check fitting dimensions and allowable air-path resistance. G1/G4/F7/F9 are the designations used in the catalog.

Catalog pages 187
Fresh-air adapterAir

Fresh-air adapter

Connects an outdoor air supply to a compatible cassette.

Features and compatibility

How it works

The adapter connects the fresh-air duct to the indoor unit. Fresh-air volume and supply-system components are determined by the ventilation design.

  • Fresh-air duct connection
  • Integration with a cassette system
  • Selected as part of the ventilation design

Where it helps

Spaces that need an organized fresh-air supply alongside air conditioning.

Compatibility

Listed for four-way cassettes and mini-cassettes. The adapter is not a fan or a complete fresh-air handling unit.

Catalog pages 37, 187
Air purification kitAir

Air purification kit

An optional kit for the indoor units specified in the catalog.

Features and compatibility

How it works

The catalog lists two kit variants with a 220–240 V, 50/60 Hz power supply. Selection depends on the indoor unit type.

  • Variant for cassettes and mini-cassettes
  • Variant for ducted and console units
  • Connected during system installation

Where it helps

When selecting additional air-treatment functions for a compatible system.

Compatibility

Cassette and ducted/console units use different kits. Cleaning performance and components must be confirmed from the selected product documentation.

Catalog pages 188
Drain pumpInstallation

Drain pump

Pumps condensate away when gravity drainage is unsuitable.

Features and compatibility

How it works

The pump forms part of the condensate drainage system. Selection depends on the indoor unit, lift height and drain-pipe route.

  • Condensate removal along the designed route
  • Several variants for different units
  • Power supply and lift-height checks

Where it helps

Concealed installations and spaces where the required drainage slope cannot be provided.

Compatibility

The catalog lists 220–240 V and 208–230 V pumps. One variant is intended for all indoor unit types except wall-mounted units; the others have specific compatibility lists.

Catalog pages 188
3D airflow panelAir

3D airflow panel

A decorative panel with louvers for distributing air in different directions.

Features and compatibility

How it works

The panel completes a slim ducted unit installation. Louvers control airflow direction, and the panel includes a temperature and humidity display.

  • Three-dimensional air distribution
  • Temperature and humidity display
  • Three sizes for different configurations

Where it helps

Interiors with a concealed ducted unit where a neat visible panel is required.

Compatibility

The table specifies slim AC/DC ducted units. Catalog panel sizes are 180 × 740 × 70, 180 × 950 × 70 and 180 × 1220 × 70 mm. Selection must match the model.

Catalog pages 144, 188
R32 leak monitoringProtection

R32 leak monitoring

Sensor, detector and shut-off unit for R32 refrigerant systems.

Features and compatibility

How it works

The catalog lists separate refrigerant detection and shut-off components. They are selected as part of the system safety design.

  • Refrigerant sensor
  • Refrigerant detector
  • Shut-off unit

Where it helps

When designing R32 systems with specified leak monitoring.

Compatibility

For the specified R32 systems only. Components, placement and operation are determined by the project and equipment documentation.

Catalog pages 187
Wind and snow protectionProtection

Wind and snow protection

Protective components for an outdoor unit installed in an exposed location.

Features and compatibility

How it works

The kit includes components for the cabinets specified in the catalog. Top, side, front and rear parts are sized to the outdoor unit.

  • Kits for several cabinet sizes
  • Outdoor installation conditions considered
  • Airflow and service-access checks

Where it helps

Open sites and roofs where the design calls for additional equipment protection.

Compatibility

The catalog labels this section “for the S5 series” and provides a specific model list. An engineer confirms suitability for the selected series.

Catalog pages 188

Branches, headers and connections

Selected with the equipment according to capacity, pipe layout and series requirements. These components are included in the project’s engineering design.

Fresh air and ventilation

Fresh air units, heat recovery ventilation and AHU connection kits are selected as part of the ventilation design.

Options are not necessarily standard equipment. Pricing and availability of selected components are available on request.

Welkin catalog Heat Recovery diagram showing cooling, heating and a water circuit
Air cooling

The ducted unit distributes cooled air through ducts and grilles.

Concept diagram · Welkin catalog
HI-FLEXi HEAT RECOVERY

More possibilities
for your building.

Cooling and hot water.

With the appropriate configuration, heat recovered from cooling rooms is used to produce hot water.

Only for appropriate Heat Recovery systems with additional equipment. This is not a standard feature of every VRF series.

Explore the series
COMPLETED PROJECTS

Our experience, in your city.

Projects from Welkin's Uzbekistan portfolio.

Ministry of Defence
Ministry of Defence
Ministry of Justice
Ministry of Justice
Tashkent Prosecutor’s Office
Tashkent Prosecutor’s Office
SQB Bank
SQB Bank
Tashkent Metallurgical Plant
Tashkent Metallurgical Plant
HY-LINE
HY-LINE
Globus
Globus
Piramit Tower
Piramit Tower
School No. 110
School No. 110
Dönerci Hamdi Usta
Dönerci Hamdi Usta
FOODCITY
FOODCITY
TBC Bank
TBC Bank
Westminster International University
Westminster International University
Modera Towers
Modera Towers
PEPSICO UZBEKISTAN
PEPSICO UZBEKISTAN
International Hotel Tashkent
International Hotel Tashkent
FROM IDEA TO OPERATION

One partner.
At every stage.

Working across Uzbekistan. A 3-year warranty on equipment and installation.

  • Equipment selection
  • Site survey
  • System design
  • Installation
  • Commissioning
  • Maintenance
LET'S DISCUSS YOUR PROJECT

From your brief —
to the right solution.

Describe your site and attach your specification. We will review your requirements and prepare a commercial proposal.

+998 (93) 700-06-66Message on Telegram

You can edit your text and replace files before submitting.