Climate equipment · Free delivery in Tashkent
Floor-standing air conditioners

Welkin KOL

In stock
Reviews
10 620 000 UZS

For Welkin KOL 24 · equipment price

Choose capacity

Capacity class. Room area is a guide.

Free delivery within Tashkent

Installation quoted separately

Equipment sales in Tashkent and across Uzbekistan.

Just your name and phone. No payment — a manager confirms the details.

Specifications and package contentsAll specifications and what’s included

About this model

Welkin KOL 24 is a floor-standing split system with 7.03 kW cooling capacity and R410A refrigerant.

  • Floor-standing design
  • Remote control
  • R410A refrigerant
Description and features

Rated cooling power input is 2337 W. Detailed cooling, heating and installation specifications are listed below.

About the series

Welkin KOL is a floor-standing split system. Compare capacities, power consumption, dimensions and installation requirements. Specifications depend on the selected variant.

Designed for your comfort

Why choose this model

Floor-standing design

The column indoor unit stands on the floor.

Remote control

Adjust the air conditioner using the remote control.

R410A refrigerant

Refrigerant type and charge are listed in the specifications.

Technical specifications

Selected modelKOL 24
Full specifications
Model details
BrandWelkin
SeriesKOL
ModelKOL 24
Air conditioner typeFloor-standing
AvailabilityIn stock
Compressor capacity, W8470
Performance
Recommended area47 m²
Cooling capacity7.03 kW
Cooling capacity, BTU/h24000
Heating capacity as specified, BTU/h27000+9320
Airflow, high/medium/low, m³/h910/0/800
Outdoor airflow, m³/h3650
Indoor temperature, cooling, °C17–32
Indoor temperature, heating, °C0–30
Outdoor temperature, cooling, °C18–43
Outdoor temperature, heating, °C-7–24
Cooling application area in specification, m²32–47
Power and efficiency
Power input2.337 kW
CompressorFixed speed
Energy efficiencyNot verified
Power supply220–240 V / 1 phase / 50 Hz
Rated cooling power input, W2336.876
Rated cooling current, A11.802
Cooling EER, W/W3.01
Heating power input as specified, W2321+2730
Heating current as specified, A11.72+12.4
Heating COP, W/W3.41
System nameplate power input, W5500
System nameplate current, A25.0
Starting current in specification, A54.9
Compressor mechanismRotary
Compressor brandGMCC
Compressor power input, W2015
Compressor rated load current RLA, A9.2
Compressor locked rotor current LRA, A55
Compressor thermal protectionInternal
Compressor thermal protector locationInternal
Compressor capacitor, µF65.0
Compressor oil / charge, mlVG74 750ml
Indoor fan capacitor, µF4.5uf
Outdoor fan capacitor, µF5uf
Power plugNo plug
Comfort and controls
Noise level40 dB· Sound pressure at low indoor fan speed. The specification does not state measurement conditions.
Wi-FiTo be confirmed
Indoor fan speeds in specification, rpm540/460/400/350
Indoor sound pressure, high/medium/low, dB(A)47/0/40
Outdoor fan speed, rpm850
Outdoor sound pressure level, dB(A)59
Temperature controlRemote control
Dimensions and installation
Indoor coil: number of rows2.0
Indoor coil: tube pitch × row pitch, mm21 × 13.37
Indoor coil: fin spacing, mm1.4
Indoor coil: fin materialHydrophilic aluminum
Indoor coil: tube diameter and typeØ7 mm, internally grooved
Indoor coil section dimensions, L×H×W, mm735 × 405 × 26.74
Indoor coil: number of circuits6
Indoor dimensions, W×H×D, mm510 × 1750 × 315
Indoor packing dimensions, W×H×D, mm1910 × 430 × 655
Indoor weight, net/gross, kg38.4/49.0
Outdoor coil: number of rows2
Outdoor coil: tube pitch × row pitch, mm21 × 22
Outdoor coil: fin spacing, mm1.3
Outdoor coil: fin materialHydrophilic aluminum
Outdoor coil: tube diameter and typeØ7 mm, internally grooved
Outdoor coil dimensions, L×H×W, mm900 × 609 × 22+865 × 609 × 22
Outdoor coil: number of circuits6
Outdoor dimensions, W×H×D, mm890 × 673 × 342
Outdoor packing dimensions, W×H×D, mm995 × 740 × 398
Outdoor weight, net/gross, kg55.5/58.7
RefrigerantR410A
Refrigerant charge, kg1.92
Design pressure, high/low, MPa4.2/1.5
Pipe diameter, liquid/gas9.52 / 15.9 mm
Maximum pipe length, m25
Maximum height difference, m15
Interconnecting cable2.5 × 3/0.75 × 3
Power cable section and cores in specification4.0 × 3
Additional specifications
Set temperature range, °C17–30
Sets per 20′/40′/40′HQ container32/71/77

A specification guideline. Final sizing depends on ceiling height, glazing, occupancy and heat load.

Power consumption in cooling mode
Cooling power input

2 337 W

Rated consumption

Actual consumption depends on conditions and settings.

What’s included & documents

Full package contents and warranty documents are confirmed when ordering.

Delivery, installation & warranty

Delivery in Tashkent is free. Installation is a separate service with an agreed quote. Delivery timing and warranty terms are confirmed before purchase.

Official warranty across Uzbekistan. Duration depends on the model documents.

Delivery termsWarranty service

Owner experiences

Product reviews

Loading reviews…

Publication policy

We publish relevant product experiences, including negative reviews. Spam, abuse, personal details and unrelated content are hidden. Purchases are not verified.